Why a Grade-Name Comparison Fails Before It Starts
The judgement up front: 20#, Q355B and ASTM A234 WPB are not three names for one material, and a file that records them as interchangeable is recording an assumption, not a verified position. What can be defended in an audit is narrower — a line-by-line comparison against the governing documents, with the design and purchasing functions deciding separately whether each difference matters for the service actually specified. The comparison itself is clerical work; the judgement is not.
The comparison fails structurally before any single value is compared, because the three documents are not the same kind of document. On its published description, A234/A234M covers wrought carbon steel and alloy steel fittings for moderate and elevated temperature service. GB/T 8163-2018 is a seamless tube specification, steel tubes for fluid conveyance, and GB/T 1591-2018 is a structural steel specification for low-alloy high-strength steels. Two of the three describe different product forms before they describe different chemistries, and a comparison that opens with the composition table has already skipped the distinction that matters most.
Read the Scope Clause Before the Grade Table
The first page to open is not the composition table; it is the scope clause together with the list of normative references. The four questions below each produce a line on the comparison sheet: